Syringe Pump PP-S13 PP-S14
Body weight mode (PP-S14 only)
Occlusion pressure selected
Automatically release pressure after occlusion alarm
Automatically recognize syringe size
Preset volume infused
Total volume indicator
KVO
Fast-injection control
Lock the fast key when infusing
Lock the flow rate setting keys when infusing
Regulating flow rate conveniently
Audio and video alarms
AC and DC indicator
RS232 port
Warn of misoperation
|
|
|
|
| Specifications︰ | SPECIFICATIONS: Flow rate: 0.1ml/h~1200ml/h (0.1ml/h increments, 1ml/h increments when rate is over 1000ml/h) 50ml syringe 0.1ml/h~600ml/h (0.1ml/h increments) 30ml syringe 0.1ml/h~399.9ml/h(0.1ml/h increments) 20ml syringe Bolus rate: 1200ml/h( 50ml syringe) 600ml/h( 30ml syringe) 399ml/h( 20ml syringe) Occlusion pressure: 4N,6N Volumetric accuracy: 2%(drive accuracy 1%) Total volume: 9999ml Limited volume: 9999ml Alarm: Nearly empty, Empty, Syringe misplaced or removed, Malfunction, Forget to operate after power on, Occlusion, Infusion volume equal to preset volume, Battery near finished, Battery finished, AC power failure. Power: AC220V 22V, 50Hz 1Hz Internal battery 12V 1600mAh Nickel-hydrogen; Internal battery can work at least 4 hours at the rate of 5ml/h after charged for 16 hours (refer to IEC60601-2-24). Operation condition: a)Temperature: -5~+40 b)Humidity:30-80% Transport and store condition: a)Temperature:-40~55 b)Humidity: 95% Dimension: 307(L)*135(D)*128(H)mm Net weight: 2.1Kg(including internal battery and IV clamp;) Syringe size: 20ml\30ml and 50ml Syringe type: Total 13disposable syringe brands can be used. Following is for PP-S14 only: Range of body weight mode Dose rate 0.01~99.99ug/kg/min(0.01ug/kg/min increments) 0. 01~99.99ug/kg/h(0.01mg/kg/h increments) Body weight: 0.1~300.0kg(0.1kg increments) Drug: 0.1~999.9mg(0.1mg increments) Solution: 0.1~999.9ml(0.1ml increments)
|
| Advantages︰ | The clinical applications of the products are as follows. 1. Continuous microinfusion of the functional cardiovascular medicines in the ICU and CCU. 2. Physiological maintenance microinfusion of drugs, liquids or blood infusion in premature infants and neonates. 3. Injection of s. 4. Continuous injection of anesthetics. 5. Injection of anticoagulants during hemodialysis and extracorporeal blood circulation. 6. Injection of antitumor drugs. 7. Injection of oxytocics.
|
| Export Markets︰ | Worldwide |
| Payment Details︰ | T/T |
| Min Order︰ | one |
| Ship Date︰ | 7 working days against payment |
| Standard Met︰ | ISO9001 |
|
|
|